PT 1X2-24DC-ST

PT 1X2-24DC-ST

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    Surge Suppressors 450mA 24VDC DIN Rail

  • 数据手册
  • 价格&库存
PT 1X2-24DC-ST 数据手册
https://www.phoenixcontact.com/us/products/2856032 Surge protection plug - PT 1X2-24DC-ST - 2856032 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) PT protective connector with protective circuit for a 2-wire floating signal circuit. HART-compatible. The figure shows the PT 1x2-48DCST version Product Features  Plugs can be checked with CHECKMASTER  Installed in conjunction with the PT 1x2...-BE base element  Maximum ease of maintenance thanks to the two-piece design  Base element remains an integral part of the installation  Consistent plug-in signal circuit protection  Protection for a floating signal circuit  Impedance-neutral disconnection of plug for test and maintenance purposes     Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 19.78 GRM Custom tariff number 85363010 Country of origin Germany Technical data Dimensions Height 45 mm Width 17.7 mm Depth 52 mm Horizontal pitch 1 Div. 10/10/2014   Page 1 / 8 https://www.phoenixcontact.com/us/products/2856032 Surge protection plug - PT 1X2-24DC-ST - 2856032 Technical data Dimensions Complete module height 90 mm Complete module width 17.7 mm Complete module depth 65.5 mm Ambient conditions Ambient temperature (operation) -40 °C ... 85 °C Degree of protection IP20 General Housing material PA 6.6 Inflammability class according to UL 94 V0 Color black Standards for air and creepage distances EN 60664-1 IEC 60664-1 Surge voltage category 2 Pollution degree III Mounting type On base element Type DIN rail module, two-section, divisible Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/ShieldEarth Ground Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.00 Protective circuit IEC test classification C1 C2 C3 D1 VDE requirement class C1 C2 C3 D1 Nominal voltage UN 24 V DC Maximum continuous operating voltage UC 28 V DC 20 V AC Maximum continuous voltage UC (wire-wire) 28 V DC Maximum continuous voltage UC (wire-ground) 20 V AC Nominal current IN 450 mA (45°C) Operating effective current IC at UC ≤ 5 µA Residual current IPE ≤ 2 µA (Directly grounded) 10/10/2014   Page 2 / 8 https://www.phoenixcontact.com/us/products/2856032 Surge protection plug - PT 1X2-24DC-ST - 2856032 Technical data Protective circuit ≤ 1 µA (BE: 1x2+F) Nominal discharge current In (8/20) µs (Core-Core) 10 kA Nominal discharge current In (8/20) µs (Core-Earth) 10 kA Total surge current (8/20) µs 20 kA Max. discharge current Imax (8/20) µs maximum (Core-Core) 10 kA Max. discharge current Imax (8/20) µs maximum (Core-Earth) 10 kA Nominal pulse current Ian (10/1000) µs (Core-Core) 30 A Impulse discharge current (10/350)˽µs, peak value limp 2.5 kA Output voltage limitation at 1 kV/µs (Core-Core) spike ≤ 45 V Output voltage limitation at 1 kV/µs (Core-Earth) spike ≤ 450 V ≤ 1 kV (BE: 1x2+F) Output voltage limitation at 1 kV/µs (Core-Core) static ≤ 40 V Residual voltage at In, (conductor-conductor) ≤ 40 V Residual voltage with Ian (10/1000)µs (conductor-conductor) ≤ 50 V Voltage protection level UP (Core-Core) ≤ 70 V (C1 - 1 kV/500 A) ≤ 50 V (C3 - 25 A) ≤ 70 V (C2 - 10 kV / 5 kA) ≤ 60 V (6 kV/3 kA) Voltage protection level UP (Core-Earth) ≤ 450 V (C1 - 1 kV/500 A) ≤ 550 V (C2 - 10 kV / 5 kA) ≤ 500 V (6 kV/3 kA) Response time tA (Core-Core) ≤ 1 ns Response time tA (Core-Earth) ≤ 100 ns Input attenuation aE, sym. 0.5 dB (≤ 1 MHz) 0.5 dB (≤ 1 MHz / 50 Ω) 0.25 dB (≤ 400 kHz / 150 Ω) Cut-off frequency fg (3 dB), sym. in 50 Ohm system typ. 4.5 MHz Capacity (Core-Core) typ. 1.4 nF Resistance in series 2.2 Ω ˽10 % (7-8/11-12) Surge protection fault message None Max. required back-up fuse 500 mA (e.g. T ( IEC 127-2/III)) Surge current resistance (conductor-conductor) C2 - 10 kV/5 kA C3 - 25 A C1 - 1 kV/500 A Surge current resistance (conductor-ground) C2 - 10 kV/5 kA D1 - 2,5 kA C1 - 1 kV/500 A 10/10/2014   Page 3 / 8 https://www.phoenixcontact.com/us/products/2856032 Surge protection plug - PT 1X2-24DC-ST - 2856032 Technical data Connection data Connection method Screw connection (in connection with the base element) Connection type IN PLUGTRAB plug-in system Connection type OUT PLUGTRAB plug-in system Screw thread M3 Tightening torque 0.8 Nm Stripping length 8 mm Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 12 Connection, equipotential bonding Stripping length 8 mm Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 12 Classifications eCl@ss eCl@ss 4.0 27140201 eCl@ss 4.1 27130801 eCl@ss 5.0 27130801 eCl@ss 5.1 27130801 eCl@ss 6.0 27130807 eCl@ss 7.0 27130807 eCl@ss 8.0 27130807 ETIM ETIM 2.0 EC000943 ETIM 3.0 EC000943 ETIM 4.0 EC000943 ETIM 5.0 EC000943 10/10/2014   Page 4 / 8 https://www.phoenixcontact.com/us/products/2856032 Surge protection plug - PT 1X2-24DC-ST - 2856032 Classifications UNSPSC UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 UNSPSC 11 39121610 UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 Approvals Approvals Approvals UL Listed / GOST / GL Ex Approvals UL Listed / cUL Listed / ATEX / cULus Listed Approvals submitted Approval details UL Listed      Nominal current IN 0.45 A Nominal voltage UN 24 V GOST  GL  Accessories Accessories 10/10/2014   Page 5 / 8 https://www.phoenixcontact.com/us/products/2856032 Surge protection plug - PT 1X2-24DC-ST - 2856032 Accessories Device marking Zack marker strip - ZBN 18:UNBEDRUCKT - 2809128 Zack marker strip, Strip, white, unlabeled, can be labeled with: Plotter, Mounting type: Snap into tall marker groove, for terminal block width: 18 mm, Lettering field: 18 x 5 mm     Labeled terminal marker Zack Marker strip, flat - ZBF 5,LGS:FORTL.ZAHLEN - 0808671 Zack Marker strip, flat, Strip, white, labeled, Printed horizontally: Consecutive numbers 1 - 10, 11 - 20, etc. up to 491 500, Mounting type: Snap into flat marker groove, for terminal block width: 5 mm, Lettering field: 5.15 x 5.15 mm     Zack Marker strip, flat - ZBF 5,LGS:GERADE ZAHLEN - 0810821 Zack Marker strip, flat, Strip, white, labeled, Printed horizontally: Consecutive numbers 2 - 20, 22 - 40, etc. up to 82 - 100, Mounting type: Snap into flat marker groove, for terminal block width: 5 mm, Lettering field: 5.15 x 5.15 mm     Zack Marker strip, flat - ZBF 5,LGS:UNGERADE ZAHLEN - 0810863 Zack Marker strip, flat, Strip, white, labeled, Printed horizontally: Odd numbers 1 - 19, 21 - 39, etc. up to 81 - 99, Mounting type: Snap into flat marker groove, for terminal block width: 5 mm, Lettering field: 5.15 x 5.15 mm     Zack Marker strip, flat - ZBF 5,QR:FORTL.ZAHLEN - 0808697 Zack Marker strip, flat, Strip, white, labeled, Printed vertically: Consecutive numbers 1 - 10, 11 - 20, etc. up to 91 - 100, Mounting type: Snap into flat marker groove, for terminal block width: 5 mm, Lettering field: 5.15 x 5.15 mm     10/10/2014   Page 6 / 8 https://www.phoenixcontact.com/us/products/2856032 Surge protection plug - PT 1X2-24DC-ST - 2856032 Accessories Marker pen Marker pen - X-PEN 0,35 - 0811228 Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm     Terminal marking Zack Marker strip, flat - ZBF 5:UNBEDRUCKT - 0808642 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: Plotter, Mounting type: Snap into flat marker groove, for terminal block width: 5 mm, Lettering field: 5.1 x 5.2 mm     Zack Marker strip, flat - ZBF 5/WH-100:UNBEDRUCKT - 0808668 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: Plotter, Mounting type: Snap into flat marker groove, for terminal block width: 5 mm, Lettering field: 5.15 x 5.15 mm     Drawings 10/10/2014   Page 7 / 8 https://www.phoenixcontact.com/us/products/2856032 Surge protection plug - PT 1X2-24DC-ST - 2856032 Dimensioned drawing Circuit diagram 90 44,8 7 8 11 12 OUT IN 65,5 9 10 * 4 51,5 3 The figure shows the complete module consisting of a base element and connector Catalog photo Figure may contain other products. Phoenix Contact 2014 © - all rights reserved http://www.phoenixcontact.com 10/10/2014   Page 8 / 8
PT 1X2-24DC-ST 价格&库存

很抱歉,暂时无法提供与“PT 1X2-24DC-ST”相匹配的价格&库存,您可以联系我们找货

免费人工找货